EasyManuals Logo

Siemens SIMATIC Ident RF200 User Manual

Siemens SIMATIC Ident RF200
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Command and message frames
2.7 "SET-ANT" acknowledgement
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
17
2.7
"SET-ANT" acknowledgement
Table 2- 12 "SET-ANT" acknowledgement
Address
Designation
Value
Description
Byte 0
Frame length
0x30
Net data length of the frame - 1
byte
Byte 1 0x33
Byte 2
Command
0x30
--
Byte 3 0x30
Byte 4
Status
0x30
--
Byte 5
0x41
Byte 6
Mode
0x30
0x31 antenna on
0x31 antenna off
Byte 7
0x31 / 0x32
Table 2- 13 "SET-ANT" acknowledgement
Address
Designation
Value
Description
Byte 0
Frame length
0x30
Net data length of the frame - 1
byte
Byte 1
0x32
Byte 2
Command
0x30
--
Byte 3
0x41
Byte 4
Status
high nibble
Error code "error_Moby"
Byte 5
low nibble
2.8
"SET-RS232" command
Table 2- 14 "SET-RS232" command
Address
Designation
Value
Description
Byte 0
Frame length
0x30
Net data length of the frame - 1
byte
Byte 1
0x35
Byte 2
Command
0x42
New command
Byte 3
0x42
Byte 4
Status
0x30
--
Byte 5
0x30
Byte 6
Baud rate
0x30
0x31 19.2 kBd
0x33 57.6 kBd
0x35 115.2 kBd
Byte 7 0x31 / 0x33 / 0x35