Command and message frames
2.5 SLG STATUS (mode 1) command
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
13
Address
Designation
Value
Description
Byte 8
Command status
0x30
0x30 command is not active
0x31 command is active
Byte 9 0x30 / 0x31
Byte 10
Presence
0x30
0x30 no presence
0x31 presence
Byte 11 0x30 / 0x31
2.5
SLG STATUS (mode 1) command
Table 2- 8 SLG STATUS (mode 1) command
Address
Designation
Value
Description
Byte 0
Frame length
0x30
Net data length of the frame - 1
byte
Byte 1 0x36
Byte 2
Command
0x30
--
Byte 3
0x34
Byte 4
Status
0x30
--
Byte 5
0x30
Byte 6
Mode
0x30
Mode 1
Byte 7
0x31
Byte 8
Reserve
0x30
--
Byte 9
0x30
Byte 10
Reserve
0x30
--
Byte 11
0x30
Byte 12
Reserve
0x30
--
Byte 13
0x30
Table 2- 9 "SLG STATUS" (mode 1) acknowledgment
Address
Designation
Value
Description
Byte 0
Frame length
0x31
Net data length of the frame - 1
byte
Byte 1
0x42
Byte 2
Command
0x30
--
Byte 3
0x34
Byte 4 Status high nibble Error code "error_Moby"
Byte 5
low nibble
Byte 6
S-Info
0x30
Mode from command
Byte 7
0x31
Byte 8
Hardware
0x33
Hardware version (reader)