Command and message frames
2.11 Error messages
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
21
2.11
Error messages
The following error messages are recognized by the RF200 system and entered in the
command acknowledgement in the "status" field.
Table 2- 19 Error codes of the RF200 readers
Flashing of
red LED on
reader
Error code
Description
00
0x00
no error
02 0x01 Presence error, possible causes:
The active command was not carried out completely
The transponder left the antenna field while the command was
being processed
Communication problem between reader and transponder
05 0x05 Parameter assignment error, possible causes:
Unknown command
Incorrect parameter
Function not allowed
06 0x06 Air interface faulty
12 0x0C The transponder memory cannot be written, possible cause:
Hardware fault (memory faulty)
Write-protected transponder
13 0x0D Error in the specified memory address (access attempted to non-
existent or non-accessible memory areas).
19 0x13 Buffer overflow: Insufficient buffer available on the reader for saving
the command
20
0x14
Serious system fault (hardware fault)
21
0x15
Parameter assignment error: bad parameter in RESET command
24
0x18
Only RESET command is permitted
25
0x19
Previous command is still active
28 0x1C Communications error, possible causes:
Antenna is already turned off / Antenna is already turned on
The antenna is turned of, the command cannot be executed on
the air
external antenna has a short-circuit or is not connected
30
0x1E
Incorrect number of characters in frame
--
0x1F
Running command canceled by "RESET" command