Scan mode function extension for ASCII readers
3.4 Error messages
ASCII protocol for RF200
32 Operating Manual, 11/2016, C79000-G8976-C329-04
3.4
Error messages
Error messages
The error code is always stored in byte 2 of the acknowledgment. Error Code 00is always
output when a frame is processed without errors. Error code 00 means that the parameters
have not been accepted. The following table lists all possible error codes.
Table 3- 19 Error messages
Error code
Description
0x01
Command is unknown (in first byte of frame).
0x02 Status is unknown (in second byte of frame).
0x03
A parameter setting is faulty.
0x04
BCC is faulty (in last byte of frame).
0x05 Data could not be stored retentively
(FEPROM are not identified).
0x06 Data could not be stored retentively
(FEPROM sector cannot be deleted).
0x07 Data could not be stored retentively
(FEPROM sector cannot be programmed).