Command and message frames
2.6 "MDS-STATUS" (mode 3) command
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
15
Address
Designation
Value
Description
Byte 46
Ftim
0x30
Selected ISO mode from reset
parameter
(see section "RESET")
Byte 47 xx
Bytes 48..49 Reserved 0x30 --
Byte 50
ANT
0x30
0x31 antenna is switched on
0x32 antenna is switched off
Byte 51
0x31 / 0x32
Bytes 52..53
Reserved
0x30
--
Byte 54
ANW
0x30
Operating mode
0x30 without presence
0x31 with presence
0x34 presence with command
Byte 55 0x30 / 0x31 / 0x34
2.6
"MDS-STATUS" (mode 3) command
Table 2- 10 "MDS-STATUS" (mode 3) command
Address
Designation
Value
Description
Byte 0
Frame length
0x30
Net data length of the frame - 1
byte
Byte 1
0x35
Byte 2
Command
0x30
--
Byte 3
0x42
Byte 4
Status
0x30
--
Byte 5
0x30
Byte 6
Mode
0x30
Mode 3
Byte 7
0x33
Byte 8
Reserve
0x30
--
Byte 9
0x30
Byte 10
Reserve
0x30
--
Byte 11
0x30
Table 2- 11 "MDS-STATUS" (mode 3) acknowledgment
Address
Designation
Value
Description
Byte 0 Frame length 0x31 Net data length of the frame - 1
byte
Byte 1
0x32
Byte 2
Command
0x30
--
Byte 3
0x42
Byte 4
Status
high nibble
Error code "error_Moby"
Byte 5
low nibble

Related product manuals