Command and message frames
2.10 "ANW-MELD" message
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
19
mtag
Only single tag mode is supported
Byte 15 0x30
Byte 17 0x31
Fcon
Reserved
Ftim
ISO mode general
The RESET command can be sent to the reader at any time to initialize the parameters.
Table 2- 17 "RESET" acknowledgment
Frame length
Net data length of the frame - 1
byte
Command
--
Status
Error code "error_Moby"
Firmware version
Firmware version
Format: xx.yy
Table 2- 18 "ANW-MELD" message
Frame length
Net data length of the frame - 1
byte
Command
New command
Byte 3 0x46
Status
--