Command and message frames
2.10 "ANW-MELD" message
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
19
Address
Designation
Value
Description
Byte 14
mtag
0x30
Only single tag mode is supported
Byte 15 0x30
Byte 16
0x30
Byte 17 0x31
Byte 18
Fcon
0x30
Reserved
Byte 19
0x30
Byte 20
Ftim
0x30
ISO mode general
Byte 21
0x31
The RESET command can be sent to the reader at any time to initialize the parameters.
Table 2- 17 "RESET" acknowledgment
Address
Designation
Value
Description
Byte 0
Frame length
0x30
Net data length of the frame - 1
byte
Byte 1
0x35
Byte 2
Command
0x30
--
Byte 3
0x30
Byte 4
Status
high nibble
Error code "error_Moby"
Byte 5
low nibble
Byte 6
Firmware version
xx, high nibble
Firmware version
Format: xx.yy
Byte 7
xx, low nibble
Byte 8
yy, high nibble
Byte 9
yy, low nibble
Bytes 10..11
Reserved
0x30
--
2.10
"ANW-MELD" message
Table 2- 18 "ANW-MELD" message
Address
Designation
Value
Description
Byte 0
Frame length
0x30
Net data length of the frame - 1
byte
Byte 1
0x34
Byte 2
Command
0x30
New command
Byte 3 0x46
Byte 4
Status
0x30
--
Byte 5