Scan mode function extension for ASCII readers
3.1 Retentively enabling/disabling scan mode
ASCII protocol for RF200
24 Operating Manual, 11/2016, C79000-G8976-C329-04
Retentively enabling/disabling scan mode
You can enable scan mode by executing the “SYSTEM” command with the function identifier
“FKT = 0x08”.
SYSTEM 0xAA Retentively enable scan mode
• FKT = 0x08
• PARA = 0x01
Enable scan mode (disable ASCII mode)
Scan mode is enabled using the “SYSTEM” command, as described below:
Table 3- 1 Structure of the “SYSTEM” command
Length Com-
mand
Status FKT PARA Res.
The reader is in scan mode as soon as the command has been successfully acknowledged.
Disabling scan mode (enabling ASCII mode)
To disable scan mode, you must set the “Scan mode” parameter to the value “0x02” using
the “Change parameters” frame.
Table 3- 2 Structure of the “Change parameters” frame (binary)
0x01 0x00 0x15 0x01 0x1E 0x00 0x00
BCC
Operating
Scan mode Para Para Para Para
1)
1)
1)
1)
If scan mode is disabled with this frame, only the scan mode parameter is evaluated; all
other parameters in this frame are ignored.
You will find more information on this subject as well as parameter descriptions
1)
in the
sections “Communication in scan mode (Page 26)” and ““Change parameters” frame