Scan mode function extension for ASCII readers
3.3 Communication in scan mode
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
29
Table 3- 8 Data recordparameter, UID + user data
UID
Separator
Data
End-of-text character
Table 3- 9 Example of a UID in ISO mode
binary:
0xE0 0x04 0x01 0x00 0x54 0x75 0xC7 0x4F
ascii:
0x45
0x30
0x30
0x34
0x30
0x31
0x30
0x30
0x35
0x34
0x37
0x35
0x43
0x37
0x34
0x46
3.3.1
Change parametersframe
All parameters can be changed using this frame, including serial interface parameters.
Please note:
Acknowledgement from the reader is sent with the old settings
Subsequent scan data are sent with the new settings
The parameters can be stored in the reader either retentively or non-retentively:
In a retentive parameter assignment, the transmitted data are still available after the
reader is powered up again.
In non-retentive parameter assignment, the data are only changed for current
operation. The previous parameters are used the next time the reader is powered up.
After the parameters are accepted and the acknowledgement is sent, the reader returns
automatically to scan mode.
Table 3- 10 Change parametersframe
Command parameter
Frame parameter
Byte 1
Byte 2
Byte 3
Byte 1
...
Byte 21
BCC
Command
Status
Count
Para
...
Para
0x01
0x00
0x15
...
...
...
Table 3- 11 Change parametersframe
Command parameter
Frame parameter
Byte 1
Byte 2
Byte 3
Byte 1
...
Byte 21
BCC
Command
Status
Count
Para
...
Para
0x01
0x01
0x15
...
...
...
Table 3- 12 Change parametersframe acknowledgment
Command
Error code
BCC
0x01
0xXX