Scan mode function extension for ASCII readers
3.3 Communication in scan mode
ASCII protocol for RF200
28 Operating Manual, 11/2016, C79000-G8976-C329-04
Byte
Value
Meaning
Description
10
1
RS232
Physical interface
Physical interface setting. Only possible with RF38xR.
2 reserved
11
0
9600
Baud rate
Transmission speed setting. Applies to scan mode, test mode, and frame communi-
cation.
1 19200
2
38400
3
57600
5
115200
12
0
None
Parity
Parity bit setting. Applies to scan mode, test mode, and frame communication.
1
Even
2
Odd
13
0
UID
Data record
Combination of data that the reader automatically transfers to the host in scan mode.
1
User data
2 UID + user
data
14 + 15
0
0
User data start address
Specification of address from which the user data should be read (user dataset-
ting).
0...8192 0...8192
16 + 17
4
4
User data length
Specification of amount of user data that should be read (user datasetting).
1...1024
1...1024
18
0
ascii
Data format
Setting for data transfer type: Bytes are transferred as binary bytes or are converted
into two ASCII characters. This parameter does not apply to the separator or end-of-
text character (binary). This parameter does not apply to frame traffic either.
1
binary
19
0
CR+LF
Separator
Setting for the separator transmitted between data when UID + user datais config-
ured. Not used when UIDor user datais configured.
2C
‘.‘
1...FF Any character
(not 0)
20
0
CR+LF
End-of-text character
End-of-text character transmitted at the end of a data set; separates data from differ-
ent transponders.
1...FF Any character
(not 0)
21 1 LSB first Byte order
LSB is transmitted first (within the block size) This parameter applies only to user
data.
Examples of frame content for various parameter settings
Table 3- 6 Data recordparameter, UID
UID
End-of-text character
Table 3- 7 Data recordparameter, user data
Data
End-of-text character

Related product manuals