Transponder
5.1 Selecting the transponders
ASCII protocol for RF200
36 Operating Manual, 11/2016, C79000-G8976-C329-04
ISO transponder
Description
Article number
MDS D165
• IP65
• Memory size: 112 bytes of EEPROM user memory
• Operating temperature: -25 °C ... +85 °C
• Dimensions (L x W): 86 x 54 mm
• Smartlabel (PET) in credit card format
6GT2600-1AB00-0AX0
MDS D200
• IP67
• Memory size: 256 bytes of EEPROM user memory
• Operating temperature: -20 °C ... +60 °C
• Dimensions (L x W x H): 86 x 54 x 0.8 mm
• Credit card format
6GT2600-1AD00-0AX0
MDS D261
• IP65
• Memory size: 256 bytes of EEPROM user memory
• Operating temperature: -25 °C ... +85 °C
• Dimensions (L x W): 55 x 55 mm
• Smartlabel (PET), small design
6GT2600-1AA00-0AX0
MDS D324
• IP67; IPx9K
• Memory size: 992 bytes of EEPROM user memory
• Operating temperature: -25 °C ... +125 °C
• Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm
6GT2600-3AC00
MDS D339
• IP68; IPx9K
• Memory size: 992 bytes of EEPROM user memory
• Operating temperature: -25 °C ... +220 °C
• Dimensions (Ø x H): 85 (±0.5) x 15 (-1.0) mm
6GT2600-3AA10
MDS D400
• IP67
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature: -25 °C ... +60 °C
• Dimensions (L x W x H) 85.6 (±0.3) × 54 (±0.2) × 0.8 (±0.05) mm
6GT2600-4AD00
MDS D421
• IP67; IPx9K
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature -25 °C ... +85 °C
• Dimensions (Ø x H): 10 x 4.5 mm
6GT2600-4AE00
MDS D422
• IP68
• Memory size: 2000 bytes of FRAM user memory
• Operating temperature: -25 °C ... +85 °C
• Dimensions (Ø x H): M20 x 6 (±0.2) mm
• Can be screwed into metal (flush-mounted)
6GT2600-4AF00