Transponder
5.1 Selecting the transponders
ASCII protocol for RF200
38 Operating Manual, 11/2016, C79000-G8976-C329-04
ISO transponder
Description
Article number
MDS D522
Special version
• IP68
• Memory size: 8192 bytes of FRAM user memory
• Operating temperature: -25 °C ... +85 °C
• Dimensions (Ø x H): 18 (+0.1) x 5.2 mm
• Can be clipped into metal (flush-mounted)
6GT2600-5AF00-0AX0
MDS D524
• IP67
• Memory size: 8192 bytes of FRAM user memory
• Operating temperature: -25 °C ... +85 °C
• Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm
6GT2600-5AC00
MDS D526
• IP67; IPx9K
• Memory size: 8192 bytes of FRAM user memory
• Operating temperature: -25 °C ... +85 °C
• Dimensions (Ø x H): 50 x 3.6 mm
• Round design with mounting hole
6GT2600-4AH00
MDS D528
• IP68; IPx9K
• Memory size: 8192 bytes of FRAM user memory
• Operating temperature: -25 °C ... +85 °C
• Dimensions (Ø x H): 18 (±1) x 20 (±1) mm (without thread); thread
M8