EasyManuals Logo

Siemens Simatic IPC647C User Manual

Siemens Simatic IPC647C
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #132 background imageLoading...
Page #132 background image
Troubleshooting/FAQs
13.1 General problems
SIMATIC IPC647C
132 Operating Instructions, 12/2010, A5E02669337-02
Problem Possible cause To correct or avoid error
The USB ports are disabled in
BIOS.
Use a different USB port or enable the port.
USB 2.0 device connected and
USB 2.0 is disabled.
Enable USB 2.0.
USB device not responding.
The operating system does not
support the USB ports.
Enable USB Legacy Support for the mouse and
keyboard.
For other devices you need the USB drivers for your
operating system.
DVD/CD: The front loader
does not open.
The device is switched off or the
open/close button is disabled by a
software application.
Emergency removal of the data medium:
1. Switch off the device
2. Insert a pointed object, a pin for example, or an
opened paper clip into the emergency extraction
opening of the drive. Apply slight pressure to the
contact until the front loader opens.
3. Pull the loader further out.
After changing the hard disk,
the system does not boot from
the RAID array
RAID array does not have highest
boot priority
Set the RAID array to be first in the boot priority
order
After changing the hard disk,
"unused" is indicated for the
relevant SATA port
The system was booted without a
functioning hard disk (the
removable rack was possibly not
switched on)
Reboot the system with a functioning hard disk
Computer does not boot or
"Boot device not found" is
displayed
The boot device is not first in the
boot priority in the BIOS setup or is
excluded as a boot device
Change the boot priority of the boot device in the
Boot menu of the BIOS setup or include boot device
in the boot priority
The screen flickers when the
mouse moves or when
programs are called
DDC information is not available.
Possible causes:
Monitor does not supply DDC
information
KVM switch does not pass
through DDC information.
Y cable adapter with DVI-I for
DVI-D/VGA connector is being
used
Use a monitor that supports DDC
Use a KVM switch that passes through DDC
information
Use a basic cable adapter with DVI-I to VGA
connector.

Table of Contents

Other manuals for Siemens Simatic IPC647C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simatic IPC647C and is the answer not in the manual?

Siemens Simatic IPC647C Specifications

General IconGeneral
BrandSiemens
ModelSimatic IPC647C
CategoryIndustrial PC
LanguageEnglish

Related product manuals