EasyManua.ls Logo

Siemens Simatic IPC647C - Page 170

Siemens Simatic IPC647C
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Detailed descriptions
16.2 Bus boards
SIMATIC IPC647C
170 Operating Instructions, 12/2010, A5E02669337-02
Interrupt assignment of the edge-socket connector on the bus board with 2 x PCI
1) Host PCI-IRQ A to H is permanently assigned to IRQ 16 to 23 in APIC mode.
Host PCI-IRQ A to H is assigned to IRQ 0 to 15 automatically in PIC mode by the BIOS.
E, F are exclusive
interrupts
Comment
IRQ number
IRQ (APIC)
IRQ
Y = Interrupt in APIC mode, Z = BIOS default interrupt in PIC mode (e.g. DOS)
Host
IRQ line
1 (PCIe x16)
IRQ
PCI IRQ A
PCI IRQ B
PCI IRQ C
3 (PCI)
PCI IRQ A
PCI IRQ B
PCI IRQ C
PCI IRQ D
2 (PCI)
PCI IRQ D
Slot no.
in BIOS
ID on
enclosure
1
2
3
Z
Z
Z
Z
Z
Z
Z
Z
Z
Y
Y
Y
Y
Y
Y
Y
Y
Y
1)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A B C D E F G H
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Table of Contents

Other manuals for Siemens Simatic IPC647C

Related product manuals