EasyManua.ls Logo

Siemens SIMATIC RF185C - Page 12

Siemens SIMATIC RF185C
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Security recommendations
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
12 Operating Instructions, 04/2020, C79000-G8976-C512-03
List of available protocols
All available protocols and their ports that are used with SIMATIC RF18xC, RF18xCI are
listed below.
Table 2- 1 List of available protocols
Service/
Protocol
Protocol/
Port number
Preset port
status
Port status
configurable
Port number
configurable
Authentication
Encryption
DHCP
UDP/68
Open
--
No
No
PROFINET UDP/34964
UDP/49152-
65535
Open -- No No
HTTP
TCP/80
Open
--
--
No
No
HTTPS
TCP/443
Open
--
--
Yes
Yes
NTP
UDP/123
Closed
--
No
No
SNMP
UDP/161
Closed
--
No
No
OPC UA TCP/4840 Open Yes (when
configured)
Yes (when
configured)
EtherNet/IP TCP/44818
UDP/44818
UDP/2222
Open -- No No
XML
TCP/10001
Open
No
No
XML
TCP/10002
Closed
No
No
XML
TCP/10003
Closed
No
No
XML
TCP/10004
Closed
No
No
Syslog
UDP/514
Open
--
No
No
Explanation of the table:
Authentication
Specifies whether authentication of the communication partner takes place.
Encryption
Specifies whether the transfer is encrypted.

Table of Contents

Related product manuals