EasyManua.ls Logo

Siemens SIMATIC RF185C - List of Syslog Messages

Siemens SIMATIC RF185C
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Syslog messages
B.3 List of Syslog messages
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
203
B.3 List of Syslog messages
This section describes the Syslog messages. The structure of the messages is based on IEC
62443-3-3.
Identification and authentication of human users
Message text
{protocol}: User {user name} logged in from {ip address}.
Example
WBM: User admin logged in from 192.168.0.1.
Explanation Valid logon information that is provided during logon.
Severity
Info
Facility local0
Standard
IEC 62443-3-3 Reference: SR 1.1
Message text
{protocol}: User {user name} failed to log in from {ip address}.
Example
WBM: User admin failed to log in from 192.168.0.1.
Explanation
Incorrect user name or incorrect password specified during logon.
Severity
Error
Facility
local0
Standard
IEC 62443-3-3 Reference: SR 1.1
Message text
{protocol}: User {user name} logged out from {ip address}.
Example
WBM: User admin logged out from 192.168.0.1.
Explanation
User session completed - logged out.
Severity
Info
Facility
local0
Standard
IEC 62443-3-3 Reference: SR 1.1
Message text
{protocol}: Default user {user name} logged in from {ip address}.
Example
PNIO: Default user admin logged in from 192.168.0.1.
Explanation
Default user is logged on via the IP address.
Severity
Info
Facility local0
Standard
IEC 62443-3-3 Reference: n/a (NERC-CIP 007-R5)
User account management
Message text
Authentication was enabled.
Example Authentication was enabled.
Explanation
Authentication was enabled.
Severity
Notice
Facility
local0
Standard
IEC 62443-3-3 Reference: SR 1.3

Table of Contents