Programming via OPC UA
10.1 Supported methods/functions
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
121
Diagnosis - LastAccess
Various information on the last successful transponder access or command
Client
Client interface via which the last transponder access took place.
Command
Command that was executed during the last transponder access operation.
Identifier
Transponder which was accessed with the last command.
Timestamp Time of the last transponder access
RWData Read/written data of the last command.
Only possible with commands for reading/writing the transponder memory.
Antenna
Antenna via which the transponder was accessed with the last command.
CurrentPowerLevel Power with which the last command was executed on the transponder.
This function is only supported by UHF readers.
PC Protocol Control Word of the transponder that was accessed last.
This function is only supported by UHF readers.
Polarization Polarization with which the last command was executed on the transponder.
This function is only supported by UHF readers.
Strength RSSI value with which the last command was executed on the transponder.
This function is only supported by UHF readers.
Diagnosis - Logbook
Various log information.
LastLogEntry
The last entry in the log.
LogColumns
The headers column of the log as formatted string
DigitalIOPorts
Digital IO ports
DigitalInputs Digital inputs of the communication module
This function is only supported by the CI variants of the communication modules.
DigitalOutputs Digital outputs of the communication module
This function is only supported by the CI variants of the communication modules.
You can find the specified functions under the following path in the address area of a read