Service and maintenance
12.2 Error messages
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
164 Operating Instructions, 04/2020, C79000-G8976-C512-03
1 good MISC_ERROR_
Enabling write protection on the transponder has failed.
1 good MISC_ERROR_
The "Kill" command failed.
3 good PERMISSON_
The transponder is read/write-protected.
4 good PASSWORD_
The transponder password is incorrect. Access is denied.
5 Bad
Invalid
Argument /
good
REGION_NOT_
FOUND_ERROR
All commands:
A parameter of an OPC UA command has an invalid value.
"ReadTag"/"WriteTag" command:
The addressed memory area is not available in the current
7 good OUT_OF_RANGE_
ERROR
Address error
The address range of the transponder has been exceeded.
Possible causes:
• Start address of the command start has been incorrectly
set.
• Wrong transponder type
• The area to be written to is write-protected.
7 good OUT_OF_
The requested data is not available.
8 good NO_
IDENTIFIER
There is no transponder with the required EPC ID/UID in the
transmission window or there is no transponder at all in the
9 good MULTIPLE_
More transponders are located in the transmission window than
can be processed at the same time by the reader.
9 good MULTIPLE_
There is more than one transponder in the transmission win-
10 good READ_
Read access to the transponder has failed.
14 good WRITE_
Write access to the transponder has failed.
14 good WRITE_
Writing the EPC ID/UID on the transponder has failed.
15 good NOT_SUPPORTED_
BY_DEVICE
Unknown command
An uninterpretable XML command was sent to the reader or the
Ident profile sends an uninterpretable command to the reader.
Possible causes:
• The "AdvancedCmd" block was supplied with an incorrect
"CMD".
• The "CMD" input of the "AdvancedCmd" block was overwrit-
ten.
17 good DEVICE_NOT_
The specified read point is not active because no antenna was