Technical data
13.2 Technical specifications for RF186CI, RF188CI
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
182 Operating Instructions, 04/2020, C79000-G8976-C512-03
6GT2002-0JEx0
Electrical data
Supply voltage
2)
Rated value 24 VDC
Permitted range 20 to 30 VDC
Current consumption without reader Typ. 130 mA
Current draw via reader interfaces
max. 800 mA each, at 24 V DC
Current consumption via I/O interfaces
Class A max. 150 mA each, at 24 V DC
Class B max. 500 mA each, at 24 V DC
Mechanical data
Dimensions (W × H × D)
60 × 165 × 45 mm
Weight
Approx. 260 g
Environmental conditions
Ambient temperature
During operation
-25 ... +55 °C
During transportation and storage
-40 ... +70 °C
Degree of protection
IP67
Oscillation, vibration in operation
(according to IEC 60068-2-27)
0.75 mm (10 58 Hz)
4 g (58 150 Hz)
Shock resistance, shock in operation
(according to IEC 60068-2-6)
30 g
MTBF (at 40°C)
70 years
Approvals
CE
cULus (file E85972)
FCC Code of Federal Regulations,
CFR 47, Part 15,
Sections 15.107 and 15.109 (Class A)
PNO-certified according to Conformance
Class B
1)
Depending on the connected reader.
2)
All supply and signal voltages must be safety extra low voltage (SELV/PELV according to
IEC 61140) 24 V DC supply: Safety (electrical) isolation of low voltage (SELV/PELV acc. to
IEC 61140)