Loading...
Mounting
4.3 Use at altitudes over 2,000 m
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
25
Effects on the module availability
When the module is operated at altitudes above 2,000 m, the stronger cosmic radiation
starts having an effect on the error rate of electronic components (so-called Soft Error Rate).
In rare cases this may result in the module entering the safe state; this is especially true for
safety modules. However, the functional safety of the module remains completely
unaffected.
Currently valid markings and approvals
Note
Information on the nameplate
You will find the cur
rently valid markings and approvals on the nameplate of the
communication module. All other markings and approvals are currently based on an altitude
up to 2,000
m.