Working with S5-DOS/ST
C79000-G8576-C760-03
The PG is switched off.
PG - PLC Connection with connecting cable (4) direct or via (3),
(7) or (8):
The connectors on the connecting cable (3) with the order no.
6ES5 731-6AG00 are labelled with “PG 7xx COM 1” and
“PLC-S5”.
1. Plug the connector labelled “PG 7xx COM 1” into the COM 1
port of the PG.
2. Plug the other end of the connecting cable labelled “PLC-S5”
into the matching end of the connecting cable (7) or (8) leading
to the PLC.
It is impossible to mix up the connectors on this cable because
they are of different types.
3. Connect the PLC to the remaining free connector.
Screw or clip the connectors in place for safety.
Connecting cable (3), order no. 6ES5 731-6AG00
Connecting cable (4), order no. 6ES5 734-2xxx0
1)
Connecting cable (7), order no. 6ES5 731-0xxx0
1)
Connecting cable (8), order no. 6ES5 731-1xxx0
1)
1)
xxx
is
the
length
key.
The
cables
are
available
in
lengths
ranging
from
1
m
to
1000 m.
Please
refer
to
the
Programmers
catalog
ST
59
for
details
on
the
length
key.
Connecting a PG
with an Active TTY
Port to a PLC
Connecting Cables
for a PG with an
Active TTY Port
Installing Hardware