EasyManuals Logo

Siemens SIMATIC S7-300 Module data Technical Data

Siemens SIMATIC S7-300 Module data
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
Guide to the S7-300 documentation
CPU 31xC and CPU 31x, Technical data
1-2 Manual, Edition 08/2004, A5E00105475-05
Table 1-3 Communication between sensors/actuators and the PLC
Information on.. is available in ...
Which module is suitable for my sensor/actuator? For CPU: CPU 31xC and CPU 31x Manual, Technical Data
For signal modules: Reference manual of your signal
module
How many sensors/actuators can I connect to the module? For CPU: CPU 31xC and CPU 31x Manual, technical data
of signal modules: Reference manual of your signal module
To connect my sensors/actuators to the PLC, how do I wire
the front connector ?
S7-300, CPU 31xC and CPU 31x operating instructions:
Installation: Wiring – Wiring the front connector
When do I need expansion modules (EM) and how do I
connect them?
S7-300, CPU 31xC and CPU 31x operating instructions:
Installation: Configuring – Distribution of modules to several
racks
How to mount modules on racks / mounting rails S7-300, CPU 31xC and CPU 31x operating instructions:
Installation: Assembly – Installing modules on the mounting
rail
Table 1-4 The use of local and distributed I/O
Information on.. is available in ...
Which range of modules do I want to use? For local I/O and expansion devices: Module Data reference
manual
For distributed I/O and PROFIBUS DP: Manual of the
relevant I/O device
Table 1-5 Configuration consisting of the Central Unit (CU) and Expansion Modules (EMs)
Information on.. is available in ...
Which rack / mounting rail is most suitable for my
application?
S7-300, CPU 31xC and CPU 31x operating instructions:
Installation: Configuring
Which interface modules (IM) do I need to connect the EMs
to the CU?
S7-300, CPU 31xC and CPU 31x operating instructions:
Installation: Configuring – Distribution of modules to several
racks
What is the right power supply (PS) for my application? S7-300, CPU 31xC and CPU 31x operating instructions:
Installation: Configuring

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)