EasyManuals Logo

Siemens SIMATIC S7-300 Module data Technical Data

Siemens SIMATIC S7-300 Module data
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #148 background imageLoading...
Page #148 background image
Technical data of CPU 31xC
6.6 Technical data of the integrated I/O
CPU 31xC and CPU 31x, Technical data
6-38 Manual, Edition 08/2004, A5E00105475-05
Value
1
Value
2
Value
3
...
Value
16
Value
17
Value
1
Value
2
Value
3
...
Value
16
Value
17
1.05 ms 1.05 ms 1.05 ms
1.05 ms
1.05 ms
1.05 ms 1.05 ms 1.05 ms
1.05 ms
1.05 ms
Example of a 60-Hz parasitic frequency suppression (integration time corresponds to 16.7 ms)
1 averaged measured value
1 averaged measured value
Cycle 1
Cycle 2
Figure 6-6 60 Hz interference suppression
Note
If the interference frequency is not 50/60 Hz or a multiple thereof, the input signal must be
filtered externally.
In this case, 400 Hz frequency suppression must be configured for the respective input. This
is equivalent to a "Deactivation" of the software filter.
Inputs not connected
The three inputs of a current/voltage analog output channel that is not connected should be
bypasses and connected to M
ANA
(pin 20 of the front connector). This ensures maximum
interference resistance for these analog inputs.
Outputs not connected
In order to disconnect unused analog outputs from power, you must disable and leave them
open during parameter assignment with STEP 7.
Reference
Details (visualization and processing of analog values, for example) are found in chapter 4 of
the
Module Data
Reference Manual.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)