Memory concept
4.1 Memory areas and retentivity
CPU 31xC and CPU 31x, Technical data
4-10 Manual, Edition 08/2004, A5E00105475-05
MMC copy protection
Your MMC has an internal serial number that provides copy protection at user level. You can
read this serial number from the SSL partial list 011C
H
index 8 using SFC 51 "RDSYSST."
You can then program a STOP command, for example, in a copy-protected block if the
expected and actual serial numbers of your MCC do not tally.
Reference
SSL partial list in the instruction list,
or
in the manual
System and Standard Functions.
Information on CPU memory reset:
Operating instructions CPU 31xC and CPU31x, Commissioning, Commissioning
Modules, CPU Memory Reset by means of Mode Selector Switch
Useful life of an MMC
The useful life of an MMC depends mainly on following criteria:
1. The number of delete or programming operations,
2. External influences such as ambient temperature.
At ambient temperatures up to 60 °C, a maximum of 100,000 delete/write operations can be
performed on an MMC.
Caution
To prevent loss of data, always make sure that you do not exceed the maximum number of
delete/write operations.
See also
Operating and display elements: CPU 31xC (Page 2-1)
Operating and display elements: CPU 312, 314, 315-2 DP: (Page 2-5)
Operating and display elements: CPU 317-2 DP (Page 2-7)
Operating and display elements: CPU 31x-2 PN/DP (Page 2-9)

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)

Related product manuals