Commissioning
S7-300 Programmable Controller Hardware and Installation
8-24 A5E00105492-01
8.7 Commissioning PROFIBUS-DP
8.7.1 Commissioning PROFIBUS-DP
Prerequisites
Prerequisite for commissioning a PROFIBUS-DP network is:
A PROFIBUS-DP network has been created.
In STEP 7, you have configured the PROFIBUS-DP network and you have
assigned all network nodes a PROFIBUS-DP address and memory area (see
the Manual SIMATIC, STEP 7 V5.x; Configuring hardware and connections with
STEP 7 V5.x).
Note that you must also set address switches in some of the DP slaves (see the
description of the respective DP slave).
Software requirements are shown in the table below, depending on the CPU:
Table 8-6 Software requirements
CPU Software required
315-2 DP as of STEP 7 V 3.1
as of COM PROFIBUS V 3.0
316-2 DP
318-2 DP
as of STEP 7 V 5.x
as of COM PROFIBUS V 5.0
313C-2DP
314C-2DP
as of STEP 7 V 5.1 + SP 2
as of COM PROFIBUS V 5.0