Configuration
5.3 Dimensioning the gearbox
S-1FT7 synchronous motors
Configuration Manual, 09/2018, A5E45099423B AA
119
Change in characteristic due to mounted gearbox
Figure 5-8 S1 characteristic (example)
Note relating to additional characteristics:
S1
gearbox
= S1
100 K
- (S1
100 K
- S1
60 K
)
/ 2
Starting response of a motor with mounted gearbox
Note
When commissioning, increased currents can be drawn as a result of the lubricating
characteristics (inadequate distribution of oil or grease)
- and the running-in behavior of the
shaft sealing rings.