Configuration
5.4 Brake resistances (armature short-circuit braking)
S-1FT7 synchronous motors
Configuration Manual, 09/2018, A5E45099423B AA
125
External brak-
ing resistor
R
opt
/ Ω
Average braking torque
M
Br rms
/
Nm
Max. braking
torque
M
Br max
/
Nm
rms braking current I
br rms
[A]
Without external
braking resistor
With external
braking resis-
tor
Without exter-
nal braking
resistor
With external
braking resis-
tor
1FT7086-☐AF7 2.9 7 24 30 31 28
Damage to motors caused by incorrect connection
Short-circuiting 1FT713x motors that make full use of thermal class 155 without a series
resistor can cause damage to the motor.
Do not short-circuit the motors without a series resistor.