Service and maintenance   
7.4 Performing a firmware and project update 
  SIMOTION D4x5-2 
332  Commissioning and Hardware Installation Manual, 02/2012 
Requirement (firmware update) 
You can find the latest firmware for SIMOTION D:  
●  On the SIMOTION SCOUT DVDs (e.g. at ...\3_D4xx\Firmware\V4.2\....). 
●  At the following Internet address 
(http://support.automation.siemens.
com/WW/view/en/31045047). 
Upgrading the SIMOTION D automatically updates the firmware of all connected SINAMICS 
DRIVE-CLiQ components.    
 
 
Note 
Observe the information in the the Readme files and the upgrade instructions included in the 
scope of delivery of new SIMOTION versions. 
Use only CompactFlash cards that have been released for SIMOTION D and have an 
appropriate and correct boot loader version. 
 
You can find the compatibility relationships in the SIMOTION SCOUT Add-Ons "Software 
products" compatibility list, as well as at the following Internet address 
(http://support.automation.siemens.
com/WW/view/en/18857317). 
 
NOTICE 
 
The upgrade operation deletes all project data and parameters from the CompactFlash 
card! 
 
Requirement (project update) 
You have upgraded your project and, if necessary, adapted the device type and device 
version, see Section Adapting a project (Upgrading the projec
t / Replacing the SIMOTION 
controller) (Page 319). 
7.4.3  Upgrade via IT DIAG 
The SIMOTION D features an integrated Web server.  
In addition to customized Web pages and comprehensive device/diagnostic information, one 
of the options that IT DIAG offers is performing firmware and project upgrades using a 
standard PC with Internet Explorer.  
As of firmware version V4.2, it is no longer necessary to purchase licenses for SIMOTION IT 
DIAG and SIMOTION IT OPC XML-DA. 
Detailed information can be found in the  
SIMOTION IT Ethernet-Based HMI and Diagnostic Functions
 Diagnostics Manual. 
See also 
Upgrade via device update tool (upgrading SIMOTION devices) (Page 333)