Commissioning via the built-in BOP
5.6 Function commissioning
SINAMICS V20 Converter
114 Operating Instructions, 10/2019, A5E34559884-012
Function diagram
Description:
The blockage clearing mode is enabled when an ON command is issued, and the following
sequence is performed:
Ramp or step (depending on P3363) to P3361 Hz in opposite direction to the setpoint
For P3364 repetitions:
Ramp down to 0 Hz using normal ramp time as specified in P1121
Ramp or step (depending on P3363) to P3361 Hz in opposite direction to the setpoint
Revert to "normal" setpoint and allow output to ramp using P1120.