Commissioning via the built-in BOP
5.1 The built-in Basic Operator Panel (BOP)
SINAMICS V20 Converter
Operating Instructions, 10/2019, A5E34559884-012
61
"A"
"G"
"N"
"T"
"B"
"H"
"O"
"U"
"C"
"I"
"P"
"V"
"D"
"J"
"Q"
"X"
"E"
"L"
"R"
"Y"
"F"
"M"
"S"
"Z"
0 to 9
"?"
5.1.6 LED states
The SINAMICS V20 has only one LED for status indications. The LED can display orange,
green, or red.
If more than one converter state exists, the LED displays in the following order of priority:
Parameter cloning
Commissioning mode
All faults
Ready (no fault)
For example, if there is an active fault when the converter is in the commissioning mode, the
LED flashes green at 0.5 Hz.
Converter state
LED color
Power up Orange
Ready (no fault) Green
Commissioning mode Slow flashing green at 0.5 Hz
All faults Fast flashing red at 2 Hz
Parameter cloning Flashing orange at 1 Hz