Parameter list
8.2 Parameter list
SINAMICS V20 Converter
Operating Instructions, 10/2019, A5E34559884-012
217
Displays power factor for motor.
Value is calculated internally if P0308 (rated motor cosφ) set to 0; otherwise, value entered in P0308 is
Displays rated motor torque.
Value is calculated from P0307 (rated motor power) and P0311 (rated motor speed). r0333[Nm] =
(P0307[kW] * 1000)/((P0311[1/min]/60) * 2 * Pi)
Selects motor cooling system used.
Self-cooled: Shaft mounted fan attached motor
Force-cooled: Separately powered cooling fan
Self-cooled and internal fan
Force-cooled and internal fan
P0340[0...2]
Calculation of motor pa-
rameters
0 - 4 0 T - DDS U16 2
Calculates various motor parameters.
P0341[0...2] Motor inertia [kg*m^2]
P0342[0...2] Total/motor inertia ratio
P0344[0...2] Motor weight
P0346[0...2] Magnetization time
P0347[0...2] Demagnetization time
P0350[0...2] Stator resistance (line-to-line) x x
P0352[0...2] Cable resistance
P0354[0...2] Rotor resistance
P0356[0...2] Stator leakage inductance
P0358[0...2] Rotor leakage inductance
P0360[0...2] Main inductance
P0625[0...2] Surrounding motor temperature
P1253[0...2] Controller output limitation
P1316[0...2] Boost end frequency
P1338[0...2] Resonance damping gain V/f
P1341[0...2] Imax controller integral time
P1345[0...2] Imax voltage ctrl. prop. gain
P1346[0...2] Imax voltage ctrl. integral time
P2002[0...2] Reference current
P2003[0...2] Reference torque
P2185[0...2] Upper torque threshold 1
P2187[0...2] Upper torque threshold 2
P2189[0...2] Upper torque threshold 3