Technical specifications
SINAMICS V20 Converter
Operating Instructions, 10/2019, A5E34559884-012
349
Single phase AC 230 V converters
Current rating [A] at PWM frequency
PWM frequency range: 2 kHz to 16 kHz (default: 8 kHz)
AA/AB 0.12 0.9 0.6 0.5 0.9 0.6 0.5 0.9 0.6 0.5
0.7 0.5
C 3.0 12.5 8.7 6.3 11.6 8.2 5.7 10.2 7.1 5.0 9.5 6.8 4.8
Motor control
Linear V/F, quadratic V/F, multi-point V/F, V/F with FCC
Output frequency
range
Default range: 0 Hz to 550 Hz
Maximum over-
load cycle
Rated power 0.12 kW to 15 kW
150 % rated for 60 seconds followed by 94.5 % rated for
240 seconds
Rated power 18.5 kW (HO)/22 kW (HO)
Rated power 22 kW (LO)/30 kW (LO) 110% rated for 60 seconds followed by more than 98%