Commissioning via the built-in BOP
5.6 Function commissioning
SINAMICS V20 Converter
Operating Instructions, 10/2019, A5E34559884-012
85
High/low overload (HO/LO) modes (Page 136) (P0205)
A new parameter P0205 is added to enable the HO/LO selection for heavy/low load
applications.
Imax control (Page 105) (P1340 to P1346)
JOG mode operation (Page 88) (P1055 to P1061)
List of modified parameters (P0004)
A new value is added to parameter P0004 to enable the parameter filter which allows you
to view the modified parameters.
MODBUS parity/stop bit selection (P2034, P2035)
New parameters P2034 and P2035 are added to enable MODBUS parity/stop bit
selection.
Motor blocking, load missing, belt failure detection (Page 108) (P2177 to r2198)
Motor brake controls (Page 94) (holding brake, DC brake, compound brake and dynamic
brake) (P1215 to P1237)
Motor frequency display scaling (P0511, r0512)
Motor protection with PTC sensor (Page 116) (P610)
Motor staging (Page 127) (P2370 to P2380)
Motorized potentiometer (MOP) mode selection (P1031 to r1050)
ON/OFF2 function for digital inputs (P0701)
A new value is added to parameter P0701 to run the motor with the ON command or
cancel the converter pulses with the OFF2 command.
Parameter cloning (Page 357) (P0802 to P0804, P8458)
PID controller (Page 92) (P2200 to P2355)
Pre-configured connection macros and application macros (P0507, P0717) (see also
"Setting connection macros (Page 66)" and "Setting application macros (Page 77)".)
Programmable V/f coordinates (P1320 to P1333)
Protection of user-defined parameters (P0011, P0012, P0013)
Skip frequency and resonance damping (P1091 to P1101, P1338)
Slip compensation (P1334 to P1338)
Super torque mode (Page 109) (P3350 to P3356)
Text menu display (P8553) (see also "Setting motor data (Page 64)" and "Setting
common parameters (Page 79)".)
User access level control (P0003)
USS/MODBUS communication on RS485 (P2010 to P2037) (Page 175)
Various stop mode selection (Page 86) (P0840 to P0886)
Wobble function (Page 126) (P2940 to r2955)