Installation and commissioning
3.2 Installing SINEMA RC Server
SINEMA Remote Connect - Server
32 Operating Instructions, 11/2017, C79000-G8976-C383-04
11.Log on with your user credentials. Select "System > Licenses" in the navigation and
activate the licenses. You can select between offline or online activation. You can find
additional information on this in the section "Managing licenses (Page 57)" .
Result
SINEMA RC Server was licensed for version 1.3. The previous configurations of the server
are retained. Alongside this updated server version there is a further partition on the PC with
the original V1.2 server version as a backup. Version 1.2 can continue to be started via the
boot menu of the PC if it becomes necessary to undo the update. No more devices or users
can be created in V1.2. When you restart the server, the last partition that was started is
always used.