Configuring with Web Based Management
4.6 System
SINEMA Remote Connect - Server
Operating Instructions, 11/2017, C79000-G8976-C383-04
59
If a new version is available for the SINEMA RC Server, you will find the update on the
Internet pages of Siemens Industry Online Support under the following ID:21713
(http://support.industry.siemens.com/cs/ww/en/ps/21713
)
The update must be performed in the correct order: V1.0 > V1.1 > V1.2 > V1.3
Note
System update V1.2 > V1.3
Due to changes in the basic
installation an update from V1.2 to V 1.3 is only possible using
● The user has been assigned the right "Edit system parameters".
● The latest version of SINEMA RC is downloaded. The update file has the format *.tar.gz.
● The user has access to the storage directory.
1. In the navigation, select "System > Update" and click on the "System update" tab.
2. Click the "Select file" button.
3. Navigate to the storage directory and select the file *.tar.gz.
4. Confirm your selection with the "Open" button.
5. Click the "Import" button.
The system has been updated. Depending on the type of update, individual functions, or the
entire system is restarted. To check the version following the restart, in the navigation click
"System > Overview" and check the displayed software version.
In the navigation, select "System > Update" and click on the "Power management" tab. You
have the following options for ending the system:
● Restart: To run a restart click the "Restart system" button
● Shut down: To shut the system down click the "System shutdown" button.