Setting Up
5-12 SINUMERIK 801
Start-Up
DULO
[0,AX2]=0
AX2]=0
M17 M02
End of the file
3
rd
step:Enable the leadscrew error compensation function through set MD
MD Designation Unit Axis
Example
value
Description
0
Compensation
inactive
32700 ENC_COMP_ENA
BLE
- X,Z
1
Compensation
active
Notice
When MD32700=1, the internal compensation value file in SINUMERIK 801
goes into the write protection automatically. To change a compensation value ,
first amend the compensation file and set MD32700=0 for entering the desired
value into SINUMERIK 801. Finally, reset MD32700=1.
4
th
step: Power on the system again.
Notice
The leadscrew error compensation will not be enabled until reference points
have been approached.