EasyManua.ls Logo

Siemens SINUMERIK 802S - Start-Up

Siemens SINUMERIK 802S
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing the Control System
2.2 Interfaces and cables
2-19
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Interfaces
S X1 power supply terminals (DC24V)
4–pin screw–terminal block for connecting the 24 V load power supply
S X2 RS232 interface (AXIS)
25–pin sub–D plug connector for connecting ther power sections for max. 4 stepper motor
drives
S X3 spindle interface (SPINDLE)
9–pin D–Sub connector fr connecting a spindle drive with analog interface
S X4 measuring system interfaces (ENCD)
15–pin D–Sub female connector for connecting a position encoder (incremental, RS422)
S X8 RS232 drive interface (V24)
9–pin D–Sub connector
S X9 operator terminal interface (OPI)
25–pin D–Sub female connector for connecting the operator terminal
S X10 handwheel interface (MPG)
10–pin front connector for connecting the handwheels
S X20 BEROs (DI)
10–pin front connector for connecting fast inputs including BEROs and for wiring the NC
READY relay
DI/O
S X2003 and X2004
10–pin front connector for connecting digital inputs
S X2005 and X2006
10–pin front connector for connecting digital outputs
LEDs
3 LEDs for fault and status displays
Operating elements
Start–up switch S1

Table of Contents