The following table provides an overview of the explosion-proof device variants.
Table 1-1 SIPROCESS GA700 Ex devices with analyzer modules
Device
variant
MLFB number
1)
Explosion protection type ATEX, IECEX, and CSA
certi󹪝cates
C 7MB3000-xxxxx-xxCx
7MB301x-2xxxx-xxAx
7MB302x-2xxxx-xxxx
7MB304x-2xxxx-xxxx
II 2/3G Ex ec db ic nC op is IIC T4 Gb/Gc (for occasionally
explosive gases)
The following applies for products with OXYMAT7 modules:
II 3GEx ec db ic nC op is IIC T4 Gc (for gases that are
󹪞ammable but not potentially explosive above upper 󹪞amma‐
ble limit)
2)
Rack-mounted device:
BVS 18 ATEX E 084 X
BVS 15 ATEX E 007 X
IECEx BVS 15.0007X
D 7MB3000-xxxxx-xxDx
7MB301x-2xxxx-xxBx
7MB301x-3xxxx-xxBx
7MB302x-2xxxx-xxxx
7MB304x-2xxxx-xxxx
II 3GEx ec db ic nC op is IIC T4 Gc (for non-󹪞ammable
gases)
Wall-mounted device:
BVS 14 ATEX E 154 X
IECEx BVS 14.0104X
E 7MB3000-xxxxx-xxEx
7MB301x-2xxxx-xxBx
7MB301x-3xxxx-xxBx
7MB302x-2xxxx-xxxx
7MB304x-2xxxx-xxxx
II 2G Ex pyb db ib op is IIC T4 Gb (for occasionally explosive
gases)
2)
Wall-mounted device:
BVS 14 ATEX E 153 X
IECEx BVS 14.0104X
7MB3000-xKxxx-xxEx
7MB302x-3xxxx-xxxx
II 2G Ex pxb ib IIC T3 Gb (for occasionally explosive
gases)
2)
G 7MB3000-xxxxx-xxGx
7MB301x-2xxxx-xxBx
7MB301x-3xxxx-xxBx
7MB302x-2xxxx-xxxx
7MB304x-2xxxx-xxxx
II 2G Ex pyb db ib op is IIC T4 Gb (for occasionally explosive
gases)
2)
II 3G Exec db ib nC op is IIC T4 Gc (for non-󹪞ammable
gases)
II 3D/2G Ex pyb db ib op is IIIC/IIC T65°C ... T80°C/T4 Dc/Gb
3)
(for occasionally explosive gases)
2)
II 3D Ex tc db ib op is IIIC T65°C...T80°C Dc
3)
(for non-
󹪞ammable gases)
Wall-mounted device:
BVS 14 ATEX E 153 X
IECEx BVS 14.0104X
7MB3000-xKxxx-xxEx
7MB302x-3xxxx-xxxx
II 2G Ex pxb ib IIC T3 Gb (for occasionally explosive
gases)
2)
II 3D/2G Ex pxb ib IIIC/IIC T130°C/T3 Dc/Gb (for occasion‐
ally explosive gases)
2)
II 3D Ex tc ib IIIC T130°C Dc (for non 󹪞ammable gases)
K 7MB3000-xxxxx-xxKx
7MB301x-2xxxx-xxAx
7MB302x-2xxxx-xxxx
7MB304x-2xxxx-xxxx
NI: Class I Division 2, Groups A, B, C, D, T4
Class I Zone 2, AEx/Ex ec db ic nA nC op is IIC T4 Gc (gas mix‐
tures that are occasionally between lower and upper 󹪞amma‐
ble limits)
The following applies for products with OXYMAT 7 modules:
NI: Class I Division 2, Groups A, B, C, D, T4
Class I Zone 2, AEx/Ex ec db ic nC op is IIC T4 Gc (for gases that
are 󹪞ammable above upper 󹪞ammable limit)
2)
Rack-mounted device:
CSA 23CA80153895X
Introduction
1.4Field of application
SIPROCESS GA700 rack and wall mounted devices
Compact Operating Instructions, 06/2023, A5E35134047-AB 9

Table of Contents

Other manuals for Siemens SIPROCESS GA700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROCESS GA700 and is the answer not in the manual?

Siemens SIPROCESS GA700 Specifications

General IconGeneral
BrandSiemens
ModelSIPROCESS GA700
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals