EasyManuals Logo

Siemens SIRIUS 3RT2.1 Series System Manual

Siemens SIRIUS 3RT2.1 Series
786 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #656 background imageLoading...
Page #656 background image
SIRIUS 3RA28 function modules for mounting on 3RT2 contactors
7.5 Configuration
SIRIUS Innovations
656 System Manual, 01/2011, A8E56203870002-03
7.5 Configuration
7.5.1 Configuration
3RA2811-.CW10
1
/
4
$
5$
$$
A
3/A2
3RA28
Q
t
The 3RA2811 solid-state timing relay with semiconductor output is connected to the
contactor coil in series.
Note
Contactor coil terminal A1 must not be connected.
3RA2812-.DW10
$
$
/
1
4
5$
%
6
$
$
t
Q
B1/A4
A
3/A4
35 ms
If the 3RA2812 solid-state timing relay with semiconductor output is fitted, the contactor coil
is contacted through the timing relay.
Note
Contactor coil terminals A1 and A2 must not be connected.