SIRIUS 3RA28 function modules for mounting on 3RT2 contactors
7.5 Configuration
SIRIUS Innovations
System Manual, 01/2011, A8E56203870002-03
659
3RA2816-0EW20
$&+]'&9
//
1/
)
6
)


4
$
$
4
5$ 5$



s


%
7LPH
5$
4
VV PV
<4
˂4
4
The 3RA2816 function module for star-delta (wye-delta) start has the following features:
The voltage is supplied through the plug-in contacts directly via the contactor's coil
terminals, parallel to A1/A2.
The start time in star operation is activated by switching on the contactor.
The changeover delay is 50 ms (this is a non-adjustable value).
A varistor is integrated in the basic module to attenuate contactor coil switching
overvoltages.