Functions
7.1 Output settings
SITRANS F M MAG 5000/6000
48 Operating Instructions, 12/2013, A5E02338368-002
Digital output
Digital output can be used to configure various settings:
Pulse (volume/pulse, pulse output, pulse width, pulse polarity, and time constant), see
pulse menu diagram.
Frequency (frequency output, max frequency, and time constant), see frequency menu
diagram.
Error settings (level and number), see error level menu diagram and error number menu
diagram.
Limit settings (number of setpoints, setpoint settings, and hysteresis), see direction/limit
menu diagram.
Batch settings (quantity, time and counter settings, and time constant), see batch menu
diagram.
Note
Batch settings
Only MAG 6000.
Not available in MAG 5000, MAG 5000 CT and MAG 6000 CT.
Note
When relay is set to batch function, pulse/frequency is not available on digital output.
Relay outputs
Relay output can be used to configure various settings:
Error settings (level and number), see error level menu diagram and error number menu
diagram.
Limit settings (number of setpoints, setpoint settings, and hysteresis), see direction/limit
menu diagram.
Batch settings (quantity, time and counter settings, and time constant), see batch menu
diagram.
Cleaning (cycle time), see cleaning menu diagram.
Note
Batch settings
Only MAG 6000.
Not available in MAG 5000, MAG 5000 CT and MAG 6000 CT.
Note
Cleaning
If a cleaning unit is installed together with transmitter, relay output must always be used
to operate this unit. It cannot be used for other purposes.