11.1 Technical specifications
SITRANS F M MAG 5000/6000
64 Operating Instructions, 12/2013, A5E02338368-002
MAG 6000
0.2% ± 1 mm/s (for v > 0.1 m/s)
Functions
Flow rate, 2 totalizers, low-flow cut-off, empty pipe cut-off, flow direction, error
system, operating time, uni/bidirectional flow, limit switches, pulse output, control for
cleaning and batch
Rated operation conditions
Ambient temperature
Operation
Standard IP67, 19", blind and SV versions:
-20 ... +60 °C (-4 ... +140 °F)
CT version:
-20 ... +50 °C (-4 ... +122 °F)
Storage
-40 ... +70 °C (-40 ... +158 °F)
Mechanical load
18 ... 1000 Hz, 3.17 G rms, sinusoidal in all directions to IEC 68-2-36
Degree of protection
IP67/NEMA 4X/6 to IEC 529 and DIN 40050 (1 mH
2
O 30 min.)
EMC performance
EN 61326-1 (industrial environments)
EN 61326-2-5
Display and keypad
Totalizer
Two eight-digit counters for forward, net or
reverse flow
Display
Background illumination with alphanumeric
text, 3 x 20 characters to indicate flow rate,
totalized values, settings and faults;
Reverse flow indicated by negative sign
Time constant
Time constant as current output time constant
Design
Enclosure material
Fiber glass reinforced polyamide;
optional (IP67 only): AISI 316 stainless steel
Dimensions
See dimensional drawings
Weight
0.75 kg (2 lb)
Power supply
115 ... 230 V AC +10% -15%, 50 ... 60 Hz, Fuse: 500 mA T
11 ... 30 V DC or 11 ... 24 V AC; Fuse 2 A T
Power consumption
115 ... 230 V AC: 17 VA
24 V AC: 9 VA, I
N
= 380 mA, I
ST
= 8 A (30 ms)
12 V DC: 11 W, I
N
= 920 mA, I
ST
= 4 A (250 ms)
Certificates and approvals
CE, C-UL US general purpose, C-tick, CSA/FM Class 1, div 2
Custody transfer approval (MAG
5000/6000 CT)
Cold water pattern approval: PTB OIML R 49,
MI-001
Hot water pattern approval: DANAK OIML R
75 (MAG 6000 CT)
Other media than water (milk, beer etc.)
pattern approval: DANAK OIML R 117 (MAG
6000 CT) Energy metering : PTB K7.2
Communication
MAG 5000
Without communication or HART as option
MAG 6000
Prepared for client mounted add-on modules:
HART, MODBUS RTU/RS485,
FOUNDATION Fieldbus H1, DeviceNet,
PROFIBUS PA, PROFIBUS DP as add-on
modules
MAG 5000 CT / MAG 6000 CT
No communication modules approved