EasyManua.ls Logo

Siemens SITRANS F M MAG 5000 - B.3 60 Hz Dimension dependent

Siemens SITRANS F M MAG 5000
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Factory settings
B.1 Transmitter factory settings
SITRANS F M MAG 5000/6000
92 Operating Instructions, 12/2013, A5E02338368-002
Menu item
Parameter
Factory
settings
Options
More info
Digital output
Pulse
Error, direction/limit, batch, frequency, pulse, error
number, off
Digital
output -
pulse
(Page 78)
Relay output
Error level
Error, direction/limit, cleaning, error number, off
Error level
(Page 78)
Direction/limit
switch
Off
1 setpoint, 2 setpoints
Direction/lim
it (Page 79)
Setpoints
0%
-100 ... +100%
Hysteresis
5%
0.0 ... 100%
Batch
Off
Batch
(Page 79)
Batch quantity
0
Sensor size dependent
Batch
compensation
0
-100 ... +100 m
3
Batch counter
Down
Up, down
Frequency
Off
500 Hz, 1 kHz, 5 kHz, 10 kHz
Digital
output -
frequency
(Page 78)
Time constant
5 s
0.1 ... 30 s
Pulse
On
Digital
output -
pulse
(Page 78)
Pulse polarity
Positive
Positive, negative
Pulse width
66 ms
64 μs 130 μs, 260 μs, 510 μs, 1.0 ms, 2.0 ms, 4.1
ms, 8.2 ms, 16 ms, 33, ms, 66 ms, 130 ms, 260
ms, 520 ms, 1.0 s, 2.1 s, 4.2 s
Volume/pulse
Sensor size
dependent
Dimension-dependent
Time constant
0.1 s
0.1 ... 30 s
External input
External input
Off
Batch, reset totalizer, freeze output, forced output,
off
External
input
(Page 80)
Batch
Start
Start, hold/continue, stop, Qmax 2

Table of Contents

Other manuals for Siemens SITRANS F M MAG 5000

Related product manuals