Table A-11 Totalizer, MASS 6000
MODBUS regis‐
ter
MODBUS ad‐
dress
No. of bytes Data type Description Read / write
4:02101 2100 2 Byte Totalizer 1 selection:
• 1 = Massow
• 2 = Fraction A
• 3 = Fraction B
• 4 = Volumeow
R/W
4:02102 2101 2 Byte Totalizer 1 direction:
• 0 = Reverse
• 1 = Forward
• 2 = Net
R/W
4:02103 2102 2 Byte Totalizer 2 selection:
• 1 = Massow
• 2 = Fraction A
• 3 = Fraction B
• 4 = Volumeow
R/W
4:02104 2103 2 Byte Totalizer 2 direction:
• 0 = Reverse
• 1 = Forward
• 2 = Net
R/W
A.6 Output
Table A-12 Output, MAG 6000
MODBUS regis‐
ter
MODBUS ad‐
dress
No. of bytes Data type Description Read / write
4:02201 2200 2 Byte Current Output 1 selection:
• 0 = O
• 1 = On
R/W
4:02202 2201 2 Byte Current Output 1 direction:
• 1 = Unidirectional
• 2 = Bidirectional
R/W
4:02203 2202 2 Byte Current Output 1 range:
• 0 = 0 - 20 mA
• 1 = 4 - 20 mA
• 2 = 4 - 20 mA + Alarm
R/W
4:02204 2203 4 Float Current Output 1 time constants R/W
Modbus holding registers
A.6 Output