A.9 Product identity
Table A-18 Product identity, MAG 6000
MODBUS regis‐
ter
MODBUS ad‐
dress
No. of bytes Data type Description Read / write
4:02501 2500 20 String Converter type R
4:02511 2510 20 String Converter code no. R
4:02521 2520 20 String Converter serial no. R
4:02531 2530 20 String Converter SW version R
4:02541 2540 20 String Sensor type R
4:02551 2550 20 String Sensor code no. R
4:02561 2560 20 String Sensor serial no. R
4:02571 2570 20 String Sensor size R
Table A-19 Product identity, MASS 6000
MODBUS regis‐
ter
MODBUS ad‐
dress
No. of bytes Data type Description Read / write
4:02501 2500 20 String Converter type R
4:02511 2510 20 String Converter code no. R
4:02521 2520 20 String Converter serial no. R
4:02531 2530 20 String Converter SW version R
4:02541 2540 20 String Sensor type R
4:02551 2550 20 String Sensor code no. R
4:02561 2560 20 String Sensor serial no. R
4:02571 2570 20 String Sensor size R
4:02581 2580 20 String Customer code no. R
A.10 Service info
Table A-20 Service info, MAG 6000
MODBUS regis‐
ter
MODBUS ad‐
dress
No. of bytes Data type Description Read / write
4:02701 2700 4 Double word Operating time (s) R
4:02703 2702 54 Byte array Error pending list
See Error information (Page 66)
R
4:02730 2729 54 Byte array Error log list
See Error information (Page 66)
R
Modbus holding registers
A.10 Service info
Modbus RTU RS 485