Table A-21 Service info, MASS 6000
MODBUS regis‐
ter
MODBUS ad‐
dress
No. of bytes Data type Description Read / write
4:02701 2700 4 Double word Operating time (s) R
4:02703 2702 54 Byte array USM II Error pending list
See Error information (Page 66)
R
4:02730 2729 54 Byte array USM II Error log list
See Error information (Page 66)
R
4:02757 2756 4 Float Driver signal (A) R
4:02759 2758 4 Float Pickup 1 amplitude (V) R
4:02761 2760 4 Float Pickup 2 amplitude (V) R
4:02763 2762 4 Float Sensor frequency (Hz) R
A.11 Display settings
Table A-22 Display settings, MAG 6000
MODBUS regis‐
ter
MODBUS ad‐
dress
No. of bytes Data type Description Read / write
4:02901 2900 2 Byte Language:
• 0 = English
• 1 = Deutsch
• 2 = Français
• 3 = Dansk
• 4 = Svenska
• 5 = Suomeksi
• 6 = Russian
• 7 = Español
• 8 = Italiano
• 9 = Português
• 10 = Polski
R/W
4:02902 2901 2 Byte Display line 1:
• 0 = Volumeow
• 1 = Totalizer 1
• 2 = Totalizer 2
R/W
Modbus holding registers
A.11 Display settings
Modbus RTU RS 485