Edition Remarks Product compatibility Compatibility of device integration package
05/2015 Aerated Flow
parameters
added
HW revision 02
Compact FW revision
3.02.02-01
Remote FW revision 2.02.02-01
SIMATIC PDM HART EDD: 4.00.00-00
SIMATIC PDM Service chan‐
nel
EDD: 4.00.00-00
AMS Device Manager HART EDD: 4.00.00-02
SITRANS DTM HART EDD: 4.00.00-00
375 Field Communicator
HART
EDD: 4.00.00-02
05/2014 Description of
new parame‐
ters for spare
part replace‐
ment
HW revision 02
Compact FW revision 3.02.01
Remote FW revision 2.02.01
SIMATIC PDM
AMS Device Manager
SITRANS DTM
375 Field Communicator
EDD: 3.00.00-00
12/2013 Various LUI
functions, for
example wiz‐
ards Various
transmitter
functionalities
HW revision 02
Compact FW revision 3.02.00
Remote FW revision 2.02.00
SIMATIC PDM
AMS Device Manager
SITRANS DTM
375 Field Communicator
EDD: 2.00.00
06/2012 CT chapter in‐
cluded
HW revision 01
Compact FW revision
3.00.00-10
Remote FW revision 2.00.00-30
SIMATIC PDM EDD: 1.00.00
03/2012 First edition HW revision 01
Compact FW revision 2.00.0x
Remote FW revision 2.00.0x
SIMATIC PDM EDD: 1.00.00
1.6 Checking the consignment
1. Check the packaging and the delivered items for visible damages.
2. Report any claims for damages immediately to the shipping company.
3. Retain damaged parts for clarification.
4. Check the scope of delivery by comparing your order to the shipping documents for
correctness and completeness.
WARNING
Using a damaged or incomplete device
Risk of explosion in hazardous areas.
● Do not use damaged or incomplete devices.
1.7 Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
Introduction
1.7 Security information
SITRANS FC430