Installation
2.2 Mounting the Flowmeter
SITRANS FUH1010 Quick Start
14 Operating Instructions (Compact), 12/2008, CQO:QSG010 Revision A
Pipe Mounting
For installation on pipe use Pipe Mount Kit CQO:1012XMB-1 (optional - see catalog) See
figure below.
① Clamp ④ U-Bolt Assembly for standard 2-inch
(2.38in/6.0452cm) pipe. (Hardware
supplied.)
② Mounting Bracket (Hardware not supplied for
wall mounting.)
⑤ Transducer Cable Entry Ports
③ Pipe ⑥ Position Plastic Strip Under Clamp
Figure 2-1 Pipe Mounting 1010 and Mounting Bracket Locations