EasyManua.ls Logo

Siemens Sitrans F Series - Table 3- 1 Color Codes; Figure 3-1 Input Power Connector (P8) Wiring

Siemens Sitrans F Series
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
3.1 Connecting Power
SITRANS FUH1010 Quick Start
18 Operating Instructions (Compact), 12/2008, CQO:QSG010 Revision A
5. Wire input power connector P8 for AC or DC power depending on power supply provided
as shown below. Insert wires into wire entry holes and secure by tightening wire clamp
screws (see figure below).
Note
Power Supply connector wires should be stripped AWG 12-18 stranded wire or solid
conductors.
Terminal Number 1010X-6SS2 1010X-6ZNS2 1010X-6ZPS2
1 Hot Positive Positive
2 Neutral Negative (Gnd) Negative (Gnd)
3 Ground Ground Ground
6. Plug input power connector P8 into connector J8 and secure using two captive connector
mounting screws as indicated below.
7. Secure power input cable with cable clamp to prevent wire breakage.
8. Replace Rear Housing Cover and tighten setscrew.
9. Connect the power cables to the appropriate power source previously selected from the
tables above and power up unit (100-250 VAC @ 50/60 Hz or 9-36 VDC).
Note
Loosen Wire Clamp Screw, insert stripped end of wire and then retighten.
+271(8*1'
*1'
3
$&
'&

3
Wire Clamp Screws
Connector Mounting Screws
Stripped Wire
Figure 3-1 Input Power Connector (P8) Wiring
Table 3- 1 Color Codes
HOT NEU GND
USA BK WH GRN
EU BR BL Y/GRN

Table of Contents

Other manuals for Siemens Sitrans F Series

Related product manuals