Introduction
1.2 Safety Notes
SITRANS FUH1010 Quick Start
Operating Instructions (Compact), 12/2008, CQO:QSG010 Revision A
7
Quick Start Safety Information for Hazardous Areas
Note
Ratings under this heading apply to specific model families
Check Your Model Number:
FUE1010 7ME3500, FUG1010, 7ME3610, FUH1010 7ME3600 and FUS1010 7ME3530
only;
FM-CSA installation
Read, understand and follow all safety instructions on the electronic media provided. This
equipment is rated for use in hazardous (classified) locations as stated below and must be
installed according to the 1010-304 installation drawing provided on the media. Failure to
install the equipment in the prescribed manner will result in unsafe operation. Follow all local
jurisdictional safety codes when operating this equipment. When properly installed the
equipment meets the following FM – CSA ratings.
Flow Meter
Intrinsically safe connections Class I and II, Division 1, Groups A, B, C, D, E, F and G;
Nonincendive for Class I, Division 2, Groups A, B, C and D;
Suitable for Class II Division 2 Groups F and G outdoor (Type 4X)
Temperature code T5 at an ambient of 40°C
Transducers
Intrinsically safe Class I and II, Division 1, Groups A, B, C, D, E, F and G;
Nonincendive for Class I, Division 2, Groups A, B, C and D;
Suitable for Class II Division 2 Groups F and G outdoor (Type 4X)
Temperature code T6 at an ambient of 40°C
ATEX installation
Read, understand and follow all safety instruction on the electronic media provided. This
equipment complies with Directive 94/9/EC and is rated for use in potentially explosive
atmospheres. The equipment markings are shown and explained below. Equipment must be
installed according to the 1010-389 installation drawing provided on the media. Failure to
install the equipment in the prescribed manner will result in unsafe operation. Follow all
regional safety laws when operating this equipment. When properly installed the equipment
meets the following ATEX ratings as stated in EC-Type Examination Certificate
KEMA03ATEX1134

Table of Contents

Other manuals for Siemens Sitrans F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sitrans F Series and is the answer not in the manual?

Siemens Sitrans F Series Specifications

General IconGeneral
Measurement PrincipleCoriolis, Electromagnetic, Ultrasonic
Communication ProtocolsHART, PROFIBUS, Foundation Fieldbus, Modbus
Pressure RangeVaries by model (e.g., up to 400 bar for some models)
Power Supply24 V DC or 110-230 V AC
Protection ClassIP67, IP68
Housing MaterialStainless steel, aluminum
Liner MaterialPTFE, PFA, rubber
Electrode MaterialStainless steel, Hastelloy, platinum