SFIDK.PS.029.E5.02 / SW 2.01.072
System overview
SITRANS F US
FUS060 with
SONO 3100,
SONOKIT
and SONO 3300
This operating manual is for the transmitter part of the flowmeter consisting of sensors type SONO 3100,
SONO 3300 and SONOKIT. These sensors have separate operating manuals.
FUS060
Transmitter
Enclosure IP65 (NEMA 4)
Mounting Separate wall mounting
Accuracy ± 0.5% of actual flow
Materials Die-cast aluminium
Outputs 1 current / HART / Profibus PA
1 frequency/pulse
1 relay
Display/counter Alphanumeric: flow, quantity,
error, mass flow, sound velocity, etc.
Language English, German, French, Spanish
Approval ATEX
Supply voltage
115/230 V AC
24 V AC/DC
Sensor Mild steel Stainless steel Retrofit program
Standard program and mild steel 1 or 2-tracks
Extended program
SONO 3300 SONO 3100 SONOKIT
Size
[[
[[
[mm
]]
]]
] DN 50 - DN 300 DN 100 - DN 1200 DN 100 - DN 4000
Connection EN 1092-1
examples ANSI B 16.5 150 lbs RF None
ANSI B 16.5 300 lbs RF
Pressure
[[
[[
[bar
]]
]]
] PN 10, PN 16, PN 10, PN 16,
PN 40, PN 25, PN 40 Max. PN 40
Class 150, Class 300 Class 150, Class 300
Media temperature 160 (320) 200 (394) 200 (394)
Max. °C
((
((
(°F
))
))
)
Transducer Integrated transducers SONO 3200 SONO 3200
O-ring type O-ring type
Flange type
Enclosure IP67 IP68 IP68
Approvals
ATEX ATEX ATEX